UF-5500 / 4500
2. Safety Protection
a. 2 thermostats are provided with the unit, and the heater circuit is shut down when their surface temperatures became over
320
°
F (160
°
C).
b. The heater control circuit of IC300 has the built-in function that the hardware turns off the heater control automatically if
the software does not keep turning ON the heater every a fixed time.
c. When the temperature became over 482
°
F (250
°
C), the heater control circuit of IC300 is turned off forcedly and system
reset will be executed.