127
UF-5500 / 4500
11.2.2. Simplified Troubleshooting Guide
11.2.2.1. Printing
No.
Symptom
Cause
Countermeasure
1
Failed drum cartridge
Replace drum cartridge
Failed transfer unit
Check the transfer roller and spring
Failed the high-voltage terminal
Check the high-voltage terminal
Failed the high voltage power supply board
Failed fuser unit
Check the heat roller and the pressurized roller and the spring
and the heat lamp and the thermistor
Too thick or too thin recording paper
Use the recording paper from 16lb to 24lb
2
Dirty the cover glass or the reflecting mirror
Clean the cover glass and the reflecting mirror
Dust on the path of the laser beam
Clean the path of the laser beam
Failed drum cartridge
Replace drum cartridge
Failed the heat roller or the pressurized roller
Check the heat roller and the pressurized roller
Failed LSU
Go to
LSU (Laser Scanning Unit) Section
3
Failed drum cartridge
Replace drum cartridge
Failed the gear
Check the gear
Failed the engine motor
Go to
Failed the high-voltage terminal
Check the high-voltage terminal
Failed the high voltage power supply board
Scratch on the OPC drum
Replace drum cartridge
Static electricity on the documents (when copy-
ing)
Check the connection between the parts around CIS and
“ground”, “earth”
4
Dirty or Half Darkness
Background
Failed drum cartridge
Replace drum cartridge
Dirty the pickup roller and the regist roller and
the feed roller and the eject roller and the heat
roller and the pressure roller
Clean the pickup roller and the regist roller and the feed roller
and the eject roller and the heat roller and the pressure roller
Failed the high-voltage terminal
Check the high-voltage terminal
Failed the high voltage power supply board
Dirty the recording paper path
Clean the recording paper path
5
Failed drum cartridge
Replace drum cartridge
Failed LSU
Go to
LSU (Laser Scanning Unit) Section
Failed the high-voltage terminal
Check the high-voltage terminal
Failed the high voltage power supply board
Failed the main board
Failed CIS (when copying)
6
OR
Short toner
Supply toner
Failed drum cartridge
Replace drum cartridge
Life of drum cartridge is over
Replace drum cartridge
Dirty the cover glass or the reflecting mirror
Clean the cover glass and the reflecting mirror
Failed the high-voltage terminal
Check the high-voltage terminal
Failed the high voltage power supply board
Failed the main board
Failed CIS (when copying)
7
Failed the developer roller (32mm pitch)
Replace drum cartridge
Failed the OPC drum (75mm pitch)
Replace drum cartridge
Failed the heat roller (79mm pitch)
Check the heat roller
Failed the high voltage power supply board
Too thick or too thin recording paper
Use the recording paper from 16lb to 24lb
Summary of Contents for UF-5500
Page 180: ...180 UF 5500 4500...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1...
Page 297: ...297 UF 5500 4500...
Page 305: ...305 UF 5500 4500...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52...
Page 362: ...362 UF 5500 4500...