176
UF-5500 / 4500
11.2.14. LSU Section
CROSS REFERENCE:
LSU (Laser Scanning Unit) Section
LSU
Does the POLYGON
MOTOR rotate?
Repair.
YES
NO
YES
NO
Replace LSU.
YES
Is the POLYGON
signal from Q503
Base, Q505 Base
output?
Is the signal from
pins 4, 5, 6 of CN500
output?(Refer to
LSU wave form)
Replace IC300.
NO
NO
Check the solder at R511, R501,
R502.
Is the signal from
R511(IC300 Side)
R501(IC300 Side)
R502(IC300 Side)
output?(Refer to LSU
wave form)
YES
Replace LSU.
Is the voltage at R504
(IC300 Side) about 0V?
Check the solder
at R504.
YES
NO
OK
Is the voltage at pin 5
of CN501 about 24V?
Is the voltage at pin 1
of CN500 about 5V?
Check C501, C503, C505.
Check C504,
IC501, D504, C512.
NO
NO
YES
YES
IC300 NG.
Is the solder at
Q503, Q505 OK?
YES
NO
Replace Q503/Q505.
OK?
NO