-19-
Contact
Insert
Up
A
Approx.
3 mm {0.1"}
Insert the wire until A position
and clamp the contacts.
Wire
Up
Contact
Wire
Approx. 3 mm
Insert the wire until A position
and clamp the contacts.
Contact
Up
Wire
How to Assemble the Cable with the Accessory
Connector
Strip back the cable jacket approx. 3 mm and separate
the individual conductors.
Prepare the individual conductors for clamping. Use
MOLEX band tool part number 57027-5000 (for UL-
Style Cable UL1015) or 57026-5000 (for UL-Style
UL1007) for clamping the contacts.
After clamping the contacts, push them into the proper
holes in the accessory connector of this camera until
they snap in place.
Cautions:
• Shrinking the cable-entry seal is a one-time
procedure. Do not shrink the cable-entry seal until
ascertaining that the unit is functioning.
• CONNECT THIS TO 24 V AC CLASS 2 POWER
SUPPLY ONLY.
WV-CW970 974̲ENG.qxd 07.2.1 11:31 AM ページ19