Page 3-3
ADJUSTING THE
MACHINE CONDITION
3
193C-E-MMA03-A01-01
Core Detection Adjustment
5.
Turn off the servo switch and put the
board on the transferring face of X-Y
table.
∗
Put the board on the position where the board
detection sensor is to be below.
6.
Press the SET button of board detec-
tion sensor amplifier once at the rear
side of machine.
• The SET indicating LED blinks.
7.
Take out the board and set the mask
at the front side of machine.
8.
Press the SET button of board detec-
tion sensor amplifier once at the rear
side of machine.
• The SET indicating LED lights.
OFF ( ) ON ( )
SERVO
SET button
193C-008E
18A5C2AA
Board
Board detection sensor
Sensor amplifier
SET indicating
LED
153C-IL042
SET button
Sensor amplifier
SET indicating
LED
153C-IL042
11DKC0AD