Page 1-25
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Week)
1-5-5
Checking the MR Unit
1.
Check the air pressure.
∗
Air pressure tolerant range
0.49
MPa
to 0.78
MPa
∗
If it is out of range, adjust it with the valve.
2.
Check the water receiver.
∗
Empty the water in the receiver.
193C-E-MMA01-A05-01
M02E
WARNING
BEFORE INSPECTING PNEUMATIC EQUIPMENTS, CUT OFF THE AIR SUPPLY
AND EXHAUST AIR FROM THE EQUIPMENTS.
You will have serious injury if the residual pressure actuates the machine.
Before inspecting pneumatic equipment, cut off the air supply and exhaust the air from the equipment.
Switch OFF the power.
Valve
193C-AB00
1. Unlock
2. Adjust
3. Lock
Valve operation
00DQC0AB
Water receiver
Pressure gauge