1-5
1
1
Twin-Type
4-Way Cassette Type S-125PU2E5A ×2 / U-250PE2E8A
INDOOR
MODEL
S-125PU2E5A×2
-
-
PANEL
MODEL
Standard type: CZ-KPU3 / ECONAVI type: CZ-KPU3A
-
-
OUTDOOR
MODEL
-
U-250PE2E8A
-
Branch pipe
MODEL
-
Performance test condition
ISO5151 / EN14511 / EN12102
Power supply
Ø, Hz
1Ø 50Hz
3Ø 50Hz
V
220V
230V
240V
380V
400V
415V
Min
Max
C
O
O
L
I
N
G
Capacity
kW
25.0
25.0
25.0
-
-
-
6.3
28.0
BTU/h
85300
85300
85300
-
-
-
21500
95500
Current
A
0.91 ×2
0.88 ×2
0.85 ×2
13.6
13.1
12.6
-
-
Input power
W
110 ×2
110 ×2
110 ×2
8.420k
8.420k
8.420k
-
-
TOTAL W
-
8.530k
8.530k
8.530k
-
-
Annual consumption
TOTAL kWh *4
-
-
-
-
4265
-
-
-
EER/EER CLASS
TOTAL (W/W) *5 / ("A"~"G")
-
-
-
2.93
2.93/C
2.93
-
-
Erp
*6
Pdesign
kW
-
-
-
-
-
-
-
-
SEER
(W/W)
-
-
-
-
-
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
94
93
93
-
-
Noise indoor
dB-A (H/M/L) *7
46/39/33
-
-
-
Power Level dB
61/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
61/-
-
-
Power Level dB
-
80/-
-
-
H
E
A
T
I
N
G
Capacity
kW
28.0
28.0
28.0
-
-
-
7.1
31.5
BTU/h
95500
95500
95500
-
-
-
24200
107500
Current
A
0.90 ×2
0.87 ×2
0.84 ×2
11.6
11.1
10.7
-
-
Input power
W
105 ×2
105 ×2
105 ×2
7.095k
7.095k
7.095k
-
-
TOTAL W
-
7.200k
7.200k
7.200k
-
-
COP/COP CLASS
TOTAL (W/W) *5/ ("A"~"G")
-
-
-
3.89
3.89/A
3.89
-
-
Erp
*6
Pdesign at -10°C
kW
-
-
-
-
-
-
-
-
Tbivalent
°C
-
-
-
-
-
-
-
-
SCOP
(W/W)
-
-
-
-
-
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
93
92
92
-
-
Noise indoor
dB-A (H/M/L) *7
46/39/33
-
-
-
Power Level dB
61/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
63/-
-
-
Power Level dB
-
82/-
-
-
EXTRA LOW TEMP Total capacity(kW)/Input power(W)/COP
-
-
Max Current(A) / Max Input power(W)
0.91 ×2/ 110 ×2 0.88 ×2/ 110 ×2 0.85 ×2/ 110 ×2 20.0/12.4k
20.0/12.9k
20.0/13.4k
-
Startring current(A) / Comp output(W)
-
-
-
13.6/5.5k
13.1/5.5k
12.6/5.5k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
90
120 × 2
-
Moisture removal volume
L/h(Pt/h)
9.6 (4.8×2) (20.2)
-
-
External static pressure
Pa
-
-
-
Indoor
Air flow *7
Cooling
m
3
/min (m
3
/h) (H/M/L)
37/27/19 ×2 (2220/1620/1140 ×2)
-
-
-
Heating
m
3
/min (m
3
/h) (H/M/L)
37/27/19 ×2 (2220/1620/1140 ×2)
-
-
-
Outdoor
Air flow
Cooling
m
3
/min (m
3
/h)
-
160 (9600)
-
-
Heating
m
3
/min (m
3
/h)
-
160 (9600)
-
-
Refrigerrant type / amount
g
(oz)
-
R410A 6.40k (225.8)
-
Product dimension
Height mm(inch)
319 (12-9/16)
1500 (59-1/16)
-
Width mm(inch)
840 (33-5/64)
980 (38-37/64)
-
Depth mm(inch)
840 (33-5/64)
370 (14-9/16)
-
Product dimension (Panel) H×W×D mm(inch) 33.5×950×950 (1-11/32 × 37-13/32 × 37-13/32)
-
-
Packing dimension
Height mm(inch)
365 (14-3/8)
1642 (64-41/64)
-
Width mm(inch)
898 (35-3/8)
1095 (43-7/64)
-
Depth mm(inch)
898 (35-3/8)
529 (20-53/64)
-
Weight
(NET) k
g
(lb)
25 (55)
138 (304)
-
(GROSS) k
g
(lb)
32 (71)
150 (331)
-
Panel (NET) k
g
(lb)
5 (11)
-
-
Layers limit (actually)
11 (12)
1 (2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
(Liquid)Ø12.7(1/2) (Gas)Ø25.4(1)
-
Connecting method, Standard length m (ft)
flared type, 7.5(24.6)
(Liquid)flared type (Gas)brazing connection, 7.5(24.6)
-
Pipe length range m (ft)
5~120m (16.4~393.7)
-
Indoor unit & Outdoor unit height difference m (ft)
30m(Outdoor unit located lower)/30m(Outdoor unit located higher) (98.4/98.4)
-
Add gas amount
g
/m (oz/ft)
(Liquid)Ø12.7(1/2): 80
g
(0.860)
-
Pipe length for additional gas m (ft)
30m (98.4)
-
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
*7 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830252-01_欧州_Single_8・10HP_TD_SM.indb 5
16/10/14 13:57:04
AMP Air Conditioning
www.ampair.co.uk | [email protected]