1-164
1
Single -Type
1-1. Unit Specifi cations
PEY1
2. Ceiling Type S-100PT2E5A / U-100PEY1E8
INDOOR
MODEL
S-100PT2E5A
PANEL
MODEL
OUTDOOR
MODEL
U-100PEY1E8
Branch pipe
MODEL
-
PERFORMANCE TEST CONDITION
ISO5151 / EN14511 / EN14825 / EN12102
POWER SUPPLY
ø, Hz
1ø 50Hz
3ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
CAPACITY
kW
10.0
10.0
10.0
11.5
13.5
BTU/h
34100
34100
34100
9200
39200
CURRENT
A
0.69
0.67
0.65
5.30
5.05
4.85
-
-
INPUT POWER
W
80
80
80
3.240k
3.240k
3.240k
-
-
TOTAL W
-
3.320k
3.320k
3.320k
530
4.340k
ANNUAL CONSUMPTION TOTAL kWh
*
4
-
-
1660
-
-
-
EER/EER CLASS
TOTAL(W/W)
*
5/("A"~"G")
-
-
-
3.01
3.01 / B
3.01
5.09
2.65
Erp
*
6
Pdsign
kW
-
-
-
-
10.0
-
SEER
(W/W)
-
-
-
-
6.0
-
Annual consumption
kWh
-
-
-
-
584
-
Class
-
-
-
-
A+
-
POWER FACTOR
%
-
-
-
93
93
93
-
-
NOISE INDOOR
(H/M/L)
dB-A
42/37/35
-
Power Level dB
60/55/53
-
NOISE OUTDOOR
(H/L)
dB-A
54/-
Power Level dB
70/-
H
E
A
T
I
N
G
CAPACITY
kW
10.0
10.0
10.0
2.1
13.8
BTU/h
34100
34100
34100
7200
47100
CURRENT
A
0.69
0.67
0.65
4.10
3.90
3.75
-
-
INPUT POWER
W
80
80
80
2.520k
2.520k
2.520k
-
-
TOTAL W
-
2.600k
2.600k
2.600k
410
4.000k
COP/COP CLASS
TOTAL(W/W)
*
5/("A"~"G")
-
-
-
3.85
3.85 / A
3.85
5.12
3.45
Erp
*
6
Pdsign
kW
-
-
-
-
10.0
-
Tbivalen
°C
-
-
-
-
-7
-
SCOP
(W/W)
-
-
-
-
3.9
-
Annual consumption
kWh
-
-
-
-
3590
-
Class
-
-
-
-
A
-
POWER FACTOR
%
-
-
-
93
93
93
-
-
NOISE INDOOR
(H/M/L)
dB-A
42/37/35
-
⁄
⁄
Power Level dB
60/55/53
-
NOISE OUTDOOR
(H/L)
dB-A
-
54/-
⁄
⁄
Power Level dB
-
70/-
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W)
0.69/80
0.67/80
0.65/80
9.0/5.51k
9.0/5.80k
9.0/6.02k
⁄
STARTING CURRENT(A)/COMP OUTPUT(W)
-
-
-
5.30/1.7k
5.05/1.7k
4.85/1.7k
⁄
NETWORK IMPEDANCE (ΩMAX.)
-
-
FM OUTPUT (W)
111
90
⁄
MOISTURE REMOVAL VOLUME
L/h(Pt/h)
6.0
(12.6)
-
External static pressure
Pa
-
I/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
30/25/23 (1059/883/812)
HEAT
m
3
/min (ft
3
/min)
30/25/23 (1059/883/812)
O/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
76
(2684)
HEAT
m
3
/min (ft
3
/min)
67
(2366)
REFRIGERANT TYPE, AMOUNT
g
(oz)
R410A 2.60k
(91.7)
/
P
R
O
D
I
M
HEIGHT : H mm(inch)
235 (9-1/4)
996 (39-7/32)
/
WIDTH : W mm(inch)
1590 (62-19/32)
940 (37-1/32)
/
DEPTH : D mm(inch)
690 (27-5/32)
340 (13-13/32)
/
P
A
C
D
I
M
HEIGHT : H mm
360
1136
/
WIDTH : W mm
1655
1055
/
DEPTH : D mm
820
485
/
MASS
(NET) k
g
(lb)
40 (88)
73 (161)
/
(GROSS) k
g
(lb)
49 (108)
81 (179)
/
LAYERS LIMIT (actually)
9 (10)
2 (3)
Operation
Condition
Cool O.D(DBT)
18°C ~ 32°C
-10°C ~ 43°C
Heat O.D(DBT)
16°C ~ 30°C
-15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl ared type, 5.0(16.4)
fl ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50
(16.4 ~ 164.0)
~
~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher)
(49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50
(0.538)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30
(98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.