Chapter 7
Appendix — Attaching the Smoke Cut Filter Unit (optional)
ENGLISH - 285
Attaching the Smoke Cut Filter
Fig. 3
Air filter cover
Air filter cover fixing screw
Fig. 2
Fig. 1
Smoke Cut Filter
Tabs on the projector body (d)
Tabs on the projector body (d)
Tabs on the projector body (c)
Air filter unit compartment (Smoke Cut Filter compartment)
1) Attach the Smoke Cut Filter to the projector body.
f
Insert the Smoke Cut Filter in the direction of the arrow indicated on the Smoke Cut Filter into the air filter
unit compartment (Smoke Cut Filter compartment) of the projector body.
(Fig. 1)
f
The Smoke Cut Filter has no difference between top and bottom, but is two-sided.
i)
Hook the Smoke Cut Filter frame at the bottom side to the tabs on the air filter unit compartment (Smoke Cut
Filter compartment) of the projector body (d).
(Fig. 1)
ii)
While lightly pressing inward as described with the arrow
(Fig. 1)
, hook the center area of the Smoke Cut
Filter frame at the top side to the tabs on the air filter unit compartment (Smoke Cut Filter compartment) of the
projector body (c).
(Fig. 2)
f
Confirm that the tabs on the air filter unit compartment (Smoke Cut Filter compartment) (c) and (d) are
hooked to the Smoke Cut Filter frame.
2) Slide the air filter cover toward the direction of the arrow to close (Fig. 3), and tighten the air filter
cover fixing screw using a Phillips screwdriver.
f
When the Smoke Cut Filter and the air filter cover are attached to the projector body, proceed to “Setting
the filter” (
x
page 285) next.
Note
f
Make sure that the Smoke Cut Filter is properly attached before using the projector. If it is not attached, the projector will suck in dirt and
dust causing a malfunction.
Setting the filter
Set the type of filter, and then reset the filter runtime (counter numerical value).
1) Turn on the power of the projector.
2) Press the <MENU> button on the remote control or control panel.
f
The
[MAIN MENU]
screen is displayed.
3) Press
as
to select [PROJECTOR SETUP].
4) Press the <ENTER> button.
f
The
[PROJECTOR SETUP]
screen is displayed.
5) Press
as
to select [FILTER SETTING].
6) Press the <ENTER> button.
f
The
[FILTER SETTING]
screen is displayed.
7) Press
as
to select [FILTER TYPE].
8) Press
qw
to select [SMOKE CUT].
9) Press
as
to select [FILTER COUNTER RESET], and press the <ENTER> button.