Technical information
164 - ENGLISH
Appendix
Channel
Control details
Performance
Parameter
Remark
9
Fade-out time setting
0.0s
0-15
Operate together with channel
1.
0.5s
16-31
1.0s
32-47
1.5s
48-63
2.0s
64-79
2.5s
80-95
3.0s
96-111
3.5s
112-127
4.0s
128-143
5.0s
144-159
7.0s
160-175
10.0s
176-191
No operation
192-255
10
Custom masking
OFF
0-31
To use this function, the
optional upgrade kit (Model
No.: ET-UK20) is required.
PC-1
32-63
PC-2
64-95
PC-3
96-127
No operation
128-255
11
GEOMETRY
OFF
0-15
To use PC-1, PC-2, or PC-
3, the optional upgrade kit
(Model No.: ET-UK20) is
required.
KEYSTONE
16-31
CURVED
32-47
PC-1
48-63
PC-2
64-79
PC-3
80-95
CORNER CORRECTION 96-111
No operation
112-255
Note
z
If the projector is operated with the remote control or on the control panel, or by the control command while
controlling the projector by using the Art-Net function, the setting of the DMX controller and the computer
application may be different from the projector status. In that case, set the “Lock” setting of the channel 7 to
“Operation not available” and then reset to “Operation available”. The controls of all channels become reflected
to the projector.