How to switch the input impedance (signal level) of the synchronization signal
When the ET-MD95RGB input module (sold separately) is mounted, the user can switch the input impedance
(signal level) of the synchronization signal with the analog RGB input.
Choose 75 ohm when connecting with the equipment whose synchronization output impedance is 75
Ω
such as a
signal selector, or switch to HI-Z (TTL) when connecting with the equipment whose synchronization output is TTL
such as a video card of a PC.
OPTION
SYSTEM INFORMATION
VIDEO SETTING
AUTO SETUP
SYNC. TERM
75
P IN P
ON
FUNC1
P IN P
CONTRAST MODE
HIGH
PASSWORD
:MENU SELECT
:CHANGE
Press the “MENU” button.
The MAIN MENU screen will be displayed.
Select “OPTION” with the
buttons.
MAIN MENU
PICTURE
POSITION
LANGUAGE
OPTION
TEST PATTERN
SIGNAL LIST
:MENU SELECT
ENTER:SUB MENU
Press the “ENTER” button.
The OPTION screen will be displayed.
Select “SYNC. TERM” with the “
”
buttons.
Switch the input impedance (signal
level) of the synchronization signal
with the
buttons.
• These buttons toggle between 75
Ω
and HI-Z
(TTL).
SYNC. TERM
75
Ω
HI-Z (TTL)
Amplitude: 0.6 V[p-p] to 4.0 V[p-p]
High level: 2.0 V or over
Low level: 0.8 V or lower
Input impedance
Signal level
75
Ω
1 k
Ω
• Switch the input impedance according to the input signal.
• The factory default is 75
Ω
.
• The clock phase and image position may become out of balance during this switching operation.
Please make readjustment accordingly.