[PICTURE] menu
ENGLISH
- 39
Settings
[WAVEFORM MONITOR]
By using a commercial test disk etc. and setting the
luminance level of the output (brightness) signal from
a connected external device to a value within this
projector’s recommended range, you can perform
adjustment so the display performance of the projector
can be fully leveraged.
Press the <ENTER> button.
1)
The [WAVEFORM MONITOR] menu is displayed.
z
WAVEFORM MONITOR
OFF
FULL SCAN(Y)
FULL SCAN(R)
FULL SCAN(G)
FULL SCAN(B)
SINGLE LINE SCAN(Y)
SINGLE LINE SCAN(R)
SINGLE LINE SCAN(G)
SINGLE LINE SCAN(B)
MONITOR POSITION
AUTO ADJUST
UPPER LEFT
●
Press the ▲▼ buttons to select the
2)
required item.
The waveform monitor is displayed.
z
Select [OFF] to close the waveform monitor.
z
Press the <ENTER> button.
3)
Note
For details, see “Displaying the waveform monitor” in
z
“Remote control operation”. (
page 32)
■
[MONITOR POSITION]
You can set the display position of the input waveform
during the FULL SCAN display.
Switch settings
Switch settings
[
■
AUTO ADJUST]
The luminance level of the output signal from a connected
external device is automatically adjusted by setting the
automatic waveform adjustment items.
Press the <ENTER> button.
1)
Press the ▲▼ buttons to select the
2)
required item.
Automatic waveform
adjustment items
Default
setting
[BLACK LEVEL ADJUST]
[ON]
[WHITE LEVEL ADJUST]
[ON]
[RGB ADJUST (BLACK)]
[OFF]
[RGB ADJUST (WHITE)]
[OFF]
Press the ◄► buttons to switch
3)
adjustment.
Press the ▲▼ buttons to select [START
4)
AUTO ADJUST] and press the <ENTER>
button.
[PROCESSING] message is displayed. When
z
adjustment is complete, a confirmation message for
applying results is displayed.
Select [OK] with the
5)
▲ ▼
buttons.
Press the <ENTER> button.
6)
Note
When [BLACK LEVEL ADJUST] is [ON], the display
z
signal Y (brightness) value’s black level is automatically
adjusted to the 0% position.
When [WHITE LEVEL ADJUST] is [ON], the display
z
signal Y (brightness) value’s white level is automatically
adjusted to the 100% position.
When [RGB ADJUST (BLACK)] is [ON], the display signal
z
R (Red), G (Green), and B (Blue) value’s black level are
all automatically adjusted to the 0% position.
When [RGB ADJUST (WHITE)] is [ON], the display signal
z
R (Red), G (Green), and B (Blue) value’s white level are
all automatically adjusted to the 100% position.
[AUTO ADJUST] cannot be executed if the [WAVEFORM
z
MONITOR] is [OFF].
Project the luminance adjustment signal of a commercial
z
test disk etc., and perform automatic adjustment.
However, even with an adjustment disk, correct
adjustment may not be possible if noise is included on
the disk itself or the playback device generates noise.
[AUTO ADJUST] adjusts based on the 0% and 100%
z
standard signal within the screen, so correct adjustment
cannot be performed if standard signals are not displayed
on the screen because of overscan etc., or if a signal that
is less than 0% or greater than 100% is displayed on the
screen.