Page 1-33
REGULAR
MAINTENANCE
1
Check Every 140 Hours (Once a Week)
9
. Press the SET key of the vacuum
switch once within two minutes.
∗
The display is “P-1.” (The setting value or
“P-1” appears in turn.)
10
. Press either or key of vacuum
switch, so that the vacuum switch
displays the following value.
∗
Head A is PA0 –4.0
Head B is PB0 –4.0
Head C is PC0 –4.0
e.g.) As for the head A, press or key, so
that – 37.0 – 4.0 = –41.0 appears when PA0
recorded at step 5. is – 37.0.
11
. Press the SET key of the vacuum
switch once.
∗
The display is “P-2.”
12
. Press either or of the vacuum
switch, so that the vacuum switch
displays the following value.
∗
Head A is PA0 –4.0
Head B is PB0 –4.0
Head C is PC0 –4.0
e.g.) As for the head A, press or key, so
that – 37.0 – 4.0 = – 41.0 appears when PA0
recorded at steps 5. is – 37.0.
To the next page