Page 1-14
1-3
Check Every 24 Hours (Routine)
1-3-1
Checking the MR Unit (before Operation)
Check and clean the air pressure and drain of MR unit.
Checking the MR unit
1.
Check the air pressure.
∗
Air pressure standard 0.49 MPa
∗
When the air pressure is over the standard,
adjust it with the valve. When it is less than the
standard, check that supply air (first pressure)
is within the range of 0.49 MPa to 0.78 MPa.
2.
Check the water receiver.
∗
Before the bottle is half filled, empty the water.
Air pressure gauge
1. Unlock
2. Adjust
3. Lock
4T3C-E-MMA01-A03-00
443C-302P
Valve
4T3C-AA00
443C-301P
Water receiver