Page 1-27
1
REGULAR
MAINTENANCE
1
1-4
Check Every 140 Hours (Once a Week)
1-4-1
Cleaning the Vacuum Component of the Mask Cleaning
Clean the vacuum component.
1.
Turn off the power.
2.
Open the front safety cover.
3.
Open the center safety cover, and pull
out the cleaning unit to the operator’s
side.
4.
Remove the paper tube of the take-up
roll (upper side).
∗
Draw the paper tube to the takeout lever side
and ensure that it is apart from the projection of
hinge, then pull it out of the left side of paper
tube to remove it.
∗
Put the removed paper tube to the place where
the operation is not prevented.
1E4C-E-MMA01-A06-00
Cleaning unit
Tools
4 mm hexagon Allen wrench
Required time
10 minutes
REL
EA
SE
TR
IP
O
F
F
ON
RE
S
E
T
1B4C-405P
1B4C-406P
1B4C-406P
Draw it close to the right to be
apart from this axis.