Page 1-22
1E4C-E-MMA01-A05-01
Check Every 24 Hours (Routine)
4.
Turn off the servo switch.
5.
Open the front safety cover.
6.
Clean the clamp claw, support plate,
and recognition hole of board posit-
ing unit.
∗
Clean with a cloth soaked with IPA or ethanol.
∗
Clean the recognition hole with the jig.
7.
Close the front safety cover.
8.
Turn on the servo switch.
9.
Press
UNLOCK
+ Front .
• The X-Y table moves to the origin position.
10.
Press
UNLOCK
+ Rear .
• The X-Y table moves to the back side of the
machine.
OFF ( ) ON ( )
SERVO
1B4C-402P
Cleaning jig for recognition hole
1B4C-439E
To the next page
OFF ( ) ON ( )
SERVO
1B4C-EEn-MaPt-002
1
2
Summary of Contents for KXF-1E4C