Value Range
0-2
–
0: Disable NTP
–
1: Automatically (NTP server assigned by DHCP server)
–
2: Manually (assigned via prov/web)
Default Value
0
NTP_ADDR
Value Format
String
Description
Specifies the IP address or FQDN of the NTP server.
Value Range
Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value
Empty string
Web User Interface Reference
TIME_SYNC_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, to resynchronize after having
detected no reply from the NTP server.
Value Range
10–86400
Default Value
60
TIME_QUERY_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, between synchronizations with the
NTP server.
Value Range
10–86400
Default Value
43200
Web User Interface Reference
Synchronization Interval (Page 99)
5.4.7 STUN Settings
STUN_SERV_ADDR
Value Format
String
Description
Specifies the IP address or FQDN of the STUN server.
Value Range
Max. 127 characters (IP address in dotted-decimal notation or FQDN)