Default Value
Empty string
Web User Interface Reference
TIME_SYNC_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, to resynchronize after having
detected no reply from the NTP server.
Value Range
10–86400
Default Value
60
TIME_QUERY_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, between synchronizations with the
NTP server.
Value Range
10–86400
Default Value
43200
Web User Interface Reference
Synchronization Interval (Page 100)
5.4.7 STUN Settings
STUN_SERV_ADDR
Value Format
String
Description
Specifies the IP address or FQDN of the STUN server.
Value Range
Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value
Empty string
Web User Interface Reference
STUN_SERV_PORT
Value Format
Integer
Description
Specifies the port number of the STUN server.
Value Range
1–65535
Default Value
3478
Web User Interface Reference
202
Administrator Guide
Document Version 2013-03
5.4.7 STUN Settings
Summary of Contents for KX-UT123
Page 32: ...32 Administrator Guide Document Version 2013 03 1 2 2 Firmware Update...
Page 154: ...154 Administrator Guide Document Version 2013 03 4 7 6 Restart...
Page 270: ...270 Administrator Guide Document Version 2013 03 5 7 2 SIP Settings...
Page 286: ...286 Administrator Guide Document Version 2013 03 6 3 1 Flexible Button Settings...
Page 290: ...290 Administrator Guide Document Version 2013 03 7 4 Local Firmware Update...
Page 296: ...296 Administrator Guide Document Version 2013 03 8 1 Troubleshooting...
Page 297: ...Section 9 Appendix Document Version 2013 03 Administrator Guide 297...
Page 303: ...Index Document Version 2013 03 Administrator Guide 303...
Page 311: ...Document Version 2013 03 Administrator Guide 311 Notes...