Q
I changed the FCO of a Portable Station, but the display of the Portable Station still
shows the old FCO.
A
•
Turn the Portable Station off and back on again, to force it to re-register its location.
Q
If I delete the extension number of a Portable Station, and then turn the Portable
Station off and back on again, it does not function correctly.
A
•
Do not delete the extension number of the Portable Station, as this information is
necessary for it to operate.
Numbering
Q
How do I change the extension number of a wired extension?
A
•
Change the extension number of the target port to the new number, and click
Apply
.
Next, set the port to OUS status, and then back to INS status.
Q
I changed the extension number of a wired extension while the extension was
engaged in a call, but the display still shows the previous extension number.
A
•
The extension number will not change while the extension is in use. When the
conversation is finished, set the port to OUS status, and then back to INS status.
Q
How do I change the extension numbering plan from 3-digit numbers to 4-digit
numbers?
A
•
Perform the following steps:
1.
Open the
4.9 [2-6-1] Numbering Plan—Main
screen.
2.
Enter a 2-digit number in
Leading Number
, or change
No. of Additional
Digits
from "x" to "xx".
For more details, see
What is the procedure to modify the Numbering Plan?
in
Numbering
.
Q
How do I set a 3-digit numbering plan?
A
•
There are 2 methods of creating a 3-digit numbering plan, using
4.9 [2-6-1]
Numbering Plan—Main
:
1.
Set the leading number to be 2 digits, with one additional digit. This method allows
a maximum of 10 extensions.
Example:
Leading Number = 10;
No. of Additional Digits
= x
In this example, extension numbers 100 to 109 can be used.
2.
Set the leading number to be one digit, with 2 additional digits. This method allows
a maximum of 100 extensions.
Example:
Leading Number
= 1;
No. of Additional Digits
= xx
In this example, extension numbers 100 to 199 can be used.
For more details, see
What is the procedure to modify the Numbering Plan?
in
Numbering
.
Q
What is the procedure to modify the Numbering Plan?
96
PC Programming Manual
2.7.1 Frequently Asked Questions (FAQ)
Summary of Contents for KX-TDE100
Page 10: ...Feature Programming References 977 10 PC Programming Manual Table of Contents ...
Page 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters ...
Page 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters ...
Page 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters ...
Page 103: ...Section 3 1 Configuration PC Programming Manual 103 ...
Page 457: ...Section 4 2 System PC Programming Manual 457 ...
Page 586: ...586 PC Programming Manual 4 21 2 11 2 Audio Gain Card ...
Page 587: ...Section 5 3 Group PC Programming Manual 587 ...
Page 663: ...Section 6 4 Extension PC Programming Manual 663 ...
Page 818: ...Feature Guide References None 818 PC Programming Manual 6 17 4 3 DSS Console ...
Page 820: ...820 PC Programming Manual 6 18 4 3 DSS Console DSS key data copy ...
Page 821: ...Section 7 5 Optional Device PC Programming Manual 821 ...
Page 848: ...848 PC Programming Manual 7 7 5 5 External Sensor ...
Page 849: ...Section 8 6 Feature PC Programming Manual 849 ...
Page 869: ...Section 9 7 TRS PC Programming Manual 869 ...
Page 877: ...Section 10 8 ARS PC Programming Manual 877 ...
Page 889: ...Section 11 9 Private Network PC Programming Manual 889 ...
Page 901: ...Section 12 10 CO Incoming Call PC Programming Manual 901 ...
Page 930: ...930 PC Programming Manual 12 7 10 5 Miscellaneous ...
Page 931: ...Section 13 11 Maintenance PC Programming Manual 931 ...
Page 968: ...968 PC Programming Manual 13 6 11 5 Air Synchronisation ...
Page 969: ...Section 14 Appendix PC Programming Manual 969 ...
Page 976: ...976 PC Programming Manual 14 1 4 KX TDE600 PGMPR Software File Version 3 0xxx ...
Page 977: ...Feature Programming References PC Programming Manual 977 ...
Page 1017: ...PC Programming Manual 1017 Notes ...