of the phone e.g. meter pulse billing at address 0140..015F.
27.2. Introduction
The base unit uses a 32K bit serial EEPROM (IC1) for storing volatile parameters. All parameters are
set up before the base leaves the factory. Some of these are vital for the operation of the hardware so
a set of default parameters is programmed before the actual hardware fine-tuning can be initiated.
This document lists all default settings with a short description.
In the tables below values in a range that are similar are not repeated; i.e. Address 00 to 01 contains
the value 00 simply means that the value 00 is repeated in all addresses in the range. All values in this
document are in hexadecimal notation.
Type
Name
Description
D
default
The EEPROM location is preset to the Default value by the eeprom default loader
A
adjust
The EEPROM location is set during the production test and should not be
overwritten. The value is set by the eeprom default loader only if the location
contains all 1’s (byte: 0xFF, word FFFFh), i, e. it has never been set.
-
EEPROM location which is not set at all.
d
default
Same as D but best-guess value and/or not verified.
Country
Setting
x
Default - no specific country setting, so revert to default value
27.3. EEPROM Layout
27.3.1. General Setup
Address
Default
Name
Country
Setting
Type
Description
0000-01
00 E0
EepromOscillator
x
A
Frequency adjustment
0002
20
ModulationDeviation
x
A
Modulation adjustment
0020-0024
-
RFPI (ID for Base Unit)
x
A
RFPI
0025-0026
00 00
AC (Base PIN code)
x
D
AC code
0028
00
TBR22Test
x
-
TBR22 test
0030-0034
FF .. FF
IPUI_1 (ID for H/S 1)
x
D
Ipui for handset 1. If set to FF .. FF
(5bytes) the
handset is not enrolled.
0035-0039
FF .. FF
IPUI_2 (ID for H/S 2)
x
D
Ipui for handset 2. If set to FF .. FF
(5bytes) the
handset is not enrolled.
003A-003E
FF .. FF
IPUI_3 (ID for H/S 3)
x
D
Ipui for handset 3. If set to FF .. FF
(5bytes) the
handset is not enrolled.
003F-0043
FF .. FF
IPUI_4 (ID for H/S 4)
x
D
Ipui for handset 4. If set to FF .. FF
(5bytes) the
handset is not enrolled.
60
Summary of Contents for KX-TCD410ALM
Page 21: ... To exit the operation press any time 21 ...
Page 48: ...18 FREQUENCY TABLE MHz 48 ...
Page 55: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 55 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 74: ...33 ACCESSORIES AND PACKING MATERIALS 33 1 KX TCD410ALM ALS 33 2 KX TCD412ALM ALS 74 ...
Page 75: ...33 3 KX A142ALM ALS 75 ...
Page 76: ...34 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 34 1 Base Unit 76 ...
Page 104: ...Clip Base PCB G N D S D A S C L 2 7V MODE SDA SCLK GND J104 J103 J102 J101 J100 ...
Page 106: ...PbF IC1 IC2 80 30 50 5 8 4 1 1 11 18 1 IC3 Marked ...
Page 108: ...4 1 5 8 PbF 1 28 18 IC3 IC2 IC1 11 64 1 16 17 32 49 48 33 Marked ...