Telephone Line Interface
()
Check Link
()
Note:
BBIC is IC1.
12. CHECK PROCEDURE (BASE UNIT)
12.1. Preparation
12.1.1. Equipment Required
- DECT tester: Rohde & Schwarz, CMD 60 is recommended.
- Frequency counter: it must be precise to be able to measure 1Hz
(precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
- DC power: it must be able to output at least 1A current under 9V.
- Digital multi-meter (DMM): it must be able to measure voltage and
current.
- Oscilloscope
12.1.2. JIGs and PC
- EEPROM serial JIGs
1. I2C PCB: PQZZTCD705BX
2. RS232C cable: PQZZ1CD705BX
3. Clip cable: PQZZ2CD705BX
4. DC cable: PQZZ3CD705BX
- PC which runs in DOS mode
- Batch file for setting: PQZZTCD410AL
12.2. PC Setting
12.2.1. Connections
12.2.2. PC Setting
32
Summary of Contents for KX-TCD410ALM
Page 21: ... To exit the operation press any time 21 ...
Page 48: ...18 FREQUENCY TABLE MHz 48 ...
Page 55: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 55 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 74: ...33 ACCESSORIES AND PACKING MATERIALS 33 1 KX TCD410ALM ALS 33 2 KX TCD412ALM ALS 74 ...
Page 75: ...33 3 KX A142ALM ALS 75 ...
Page 76: ...34 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 34 1 Base Unit 76 ...