- PLL Oscillator
- Detector
- Compress/Expander
- Amplifier for transmission and reception
- EEPROM: IC2
- Temporary operating parameters (for RF, etc)
Note:
Refer to
EEPROM LAYOUT (HANDSET)
().
22.2. Power Supply Circuit/Reset Circuit
Circuit Operation:
When power on the Handset, the voltage is as follows;
BATTERY(2.2 V ~ 2.6V: TP3) TP14(4V) IC3(6, 27), D3 IC1(37) IC1(39, 63) (2.65V)
The Reset signal generates R19, C23 and 2.65V.
22.3. Charge Circuit
Circuit Operation:
- When charging the handset on the Base Unit, the charge current is as
follows;
DC+(5.5V ~ 6V) D4 R43, R44 (Base)
(Handset) L4 Q2 F1 ... Battery ... BATTERY-
R21 GND L5 CHARGE-(Handset) CHARGE-(Base) GND
DC-(GND)
- When charging the handset on the Charger Unit, the charge current is
as follows;
DC+(5.5V ~ 6V) D1 R1, R2 (Charger Unit) CHARGE
+(Handset) F1 ... Battery ... BATTERY- R21 GND
CHARGE-(Handset) CHARGE-(Charger Unit) GND DC-(GND)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q2 of Handset.
Refer to Fig.101 in
Power Supply Circuit
().
22.4. Battery Low/Power Down Detector
Circuit Operation:
"Battery Low" and "Power Down" are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
- Battery Low
53
Summary of Contents for KX-TCD410ALM
Page 21: ... To exit the operation press any time 21 ...
Page 48: ...18 FREQUENCY TABLE MHz 48 ...
Page 55: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 55 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 74: ...33 ACCESSORIES AND PACKING MATERIALS 33 1 KX TCD410ALM ALS 33 2 KX TCD412ALM ALS 74 ...
Page 75: ...33 3 KX A142ALM ALS 75 ...
Page 76: ...34 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 34 1 Base Unit 76 ...
Page 104: ...Clip Base PCB G N D S D A S C L 2 7V MODE SDA SCLK GND J104 J103 J102 J101 J100 ...
Page 106: ...PbF IC1 IC2 80 30 50 5 8 4 1 1 11 18 1 IC3 Marked ...
Page 108: ...4 1 5 8 PbF 1 28 18 IC3 IC2 IC1 11 64 1 16 17 32 49 48 33 Marked ...