T
3
Features
3-152
Features
T
ime-Out, Variable
Description
Provides timers to control various features or functions.
The following timers are programmable:
System Timer Items
Range
Call Forwarding – No Answer Time-Out
1 – 12 rings
Call Park Recall Time
3 – 48 rings
DISA AA Wait Time
1 – 5 s
DISA Delayed Answer Time
0 – 6 rings
Extension-to-Outside Call Duration Time 1 – 64 min
Hold Recall Time
0 – 240 s
Intercept Routing Time-Out
3 – 48 rings
Message Waiting Ring Interval Time
0 – 64 min
Outside Line Dial Starting Time
n
✕
100 ms, n:0 – 40
Outside-to-Outside Line Call Duration Time 1 – 64 min
Pickup Dialing Waiting Time
1 – 5 s
SMDR Duration Count Starting Time
0 – 60 s
Timed Reminder Alarm Ring Time
30 – 240 s
Toll Restriction First Digit Time-Out
5 – 120 s
Toll Restriction Inter-digit Time-Out
5 – 30 s
Transfer Recall Time
0 – 48 rings
Outside Line Timer Items
CPC Signal Detection Time
Disable / 100 / 200 /
(Incoming)
300 / 400 / 500 / 600 ms
Disconnect Time
1.5 / 4.0 s
DTMF Digit Time
80 / 160 ms
Hookswitch Flash Time
Disable / 80 / 96 / 112 /
200 / 300 / 400 / 500 /
600 / 700 / 800 / 900 /
1000 / 1100 / 1200 ms
Pause Time
1.5 / 2.5 / 3.5 / 4.5 s
Extension Timer Items
Delayed Ringing Count
Disable / Immediate /
1 / 3 / 6 rings / No ring