1.3 Specifications
1.3.1 General Description
Control Bus
Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slots)
Switching
Non-blocking
Power Input
KX-NCP500
100 V AC to 130 V AC; 1.0 A/200 V AC to 240 V AC; 0.6 A; 50
Hz/60 Hz
KX-NCP1000
100 V AC to 130 V AC; 1.3 A/200 V AC to 240 V AC; 0.8 A; 50
Hz/60 Hz
Power Consumption
(when fully mounted)
KX-NCP500
51 W
(240 V: 122 VA, 200 V: 113 VA, 130 V: 100 VA, 100 V: 92 VA)
KX-NCP1000
65 W
(240 V: 142 VA, 200 V: 134 VA, 130 V: 119 VA, 100 V: 113 VA)
Maximum Power Failure Tolerance
300 ms
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
W
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Trunk
From 10
´
3-party conference call to 4
´
8-party conference call
Music on Hold (MOH)
1 port (Level Control: -6 dB to +6 dB per 3 dB)
MOH1: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -6 dB to +3 dB per 3 dB
External
1 port (Volume Control: -15 dB to +6 dB per 3 dB)
Serial Interface Port
RS-232C
1 (maximum 115.2 kbps)
RJ45 Port
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
Installation Manual
23
1.3.1 General Description
Summary of Contents for KX-NCP1000
Page 42: ...42 Installation Manual 2 1 3 Activation Key File ...
Page 134: ...134 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 146: ...146 Installation Manual 5 1 5 Troubleshooting by Error Log ...
Page 147: ...Section 6 Appendix Installation Manual 147 ...
Page 151: ...Index Installation Manual 151 ...