5-12
c75
c76
c77
c78
c79
c80
c81
c82
Ozone / suction fan
Dust collecting fan
Exhaust fan motor 4
Toner bottle motor rotation in forward
direction (Factory use only)
Toner bottle motor rotation in reverse
direction (Factory use only)
Duplex unit clutch
(When duplex unit is installed.)
Not used
Lift up motor 1
(System console upper)
Paper feed clutch 1
(System console upper)
Paper feed solenoid 1
(System console upper)
(FP-D250/D350)
When
CN6-1
is +24V, ozone / suction fan
rotates.
When
CN6-7
is +24V, dust collecting fan rotates.
When
CN6-2
is +24V, exhaust fan 4 rotates.
(FP-D450/D600)
When
CN6-1
is +24V, ozone / suction fan
rotates.
When
CN6-7
is +24V, dust collecting fan rotates.
When
CN18-15
is +24V, exhaust fan 4 rotates.
(FP-D250/D350)
When
CN12-15
becomes 0V pulse, motor
rotates forward direction.
(FP-D450/D600)
When
CN12-15
becomes 0V pulse, motor
rotates forward direction.
(FP-D250/D350)
When
CN12-18
becomes 0V pulse, motor
rotates reverse direction.
(FP-D450/D600)
When
CN12-18
becomes 0V pulse, motor
rotates reverse direction.
(FP-D250/D350)
When
CN654-1
becomes 0V from +24V, clutch
operates.
(FP-D450/D600)
When
CN654-1
becomes 0V from +24V, clutch
operates.
(FP-D250/D350)
When CN603-1 is +24V, motor rotates lifting up.
(FP-D450/D600)
When CN603-1 is +24V, motor rotates lifting up.
(together with upper limit control)
(FP-D250/D350)
When CN610-3 becomes 0V from +24V, clutch
operates.
(FP-D450/D600)
When CN610-3 becomes 0V from +24V, clutch
operates.
(FP-D250/D350)
When CN610-4 becomes 0V from +24V,
solenoid operates.
(FP-D450/D600)
When CN610-4 becomes 0V from +24V,
solenoid operates.
Code
No.
Item
Function