L shaped installation
17
To install Factory line 100 or 60 in a shape of L , use the Joiner L.
●Since joiner pins used for the duct connection are
provided on each end of the Joiner L, the joiner pins
side of the duct is not available for the connection.
Consequently, cut the duct on the joiner pins side by
40 mm in length as shown in the figure.
●Since joiner pins used for the duct connection
are provided on each end of the Joiner L, use
the auxiliary duct unit of 1 m in length to
connect the ducts.
●Cut the ribs (in three places) of the duct using
a drill of φ3 mm in diameter (10 to 11 mm in
depth).
●Thoroughly remove burrs and chips from the cut
surface.
(Be sure to chamfer the inner surface of the
conductors in particular.)
●Cutting the duct
Feed-in cap
End cap
End cap
Duct
Duct
Duct
Joiner L
Feed-in cap
Joiner L
Auxiliary duct(L=1m)
(DH2310)
40 mm cutting
Joiner pin
Cut by 40 mm.
Cutting position
Rib
φ3-mm
drill
Notes
●
The Factory Line duct needs to be cut.
●
Adjust the polarity of the duct.
Notes
●
The auxiliary duct unit (DH2310) is required.
Cutting of the duct is not allowed.
●
Adjust the polarity of the duct.
Notes
●
Using an power saw may cause insulating coating to peel
or burn.
●
To cut the ribs, prevent the exposure of the conductors and
cores.
Cut by 10 or 11 mm in length from the cut surface.
The ribs 3 places
Cut by 10 to 11 mm in length
from the cut surface.
Cut surface
Conductors
〈Factory Line 100〉
The Factory Line 100 duct needs to be cut.
■ L-shaped installation
〈Factory Line 60〉
The auxiliary duct unit (DH2310) is required. Do not cutting of the Fact-line 60 duct.
■ L-shaped installation