![Panasonic CS-E9PD3EA Service Manual Download Page 83](http://html1.mh-extra.com/html/panasonic/cs-e9pd3ea/cs-e9pd3ea_service-manual_4251932083.webp)
83
15.5.16 F11 (4-way Valve Switching Failure)
Malfunction Decision Conditions
When indoor heat exchanger is cold during heating (except deice) or when indoor heat exchanger is hot during
cooling and compressor operating, the 4-way valve is detected as malfunction.
Malfunction Caused
Indoor heat exchanger (pipe) thermistor
4-way valve malfunction
Troubleshooting
* Check gas side pipe – for hot gas flow in cooling mode