12.2 Quiet Operation (Cooling Mode/Cooling area of Soft Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1 When one of the following conditions is satisfied, quiet operation stops:
a.
Powerful button is pressed.
b.
Stop by OFF/ON switch.
c.
Timer “off” activates.
d.
Quiet button is pressed again.
2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5 During quiet operation, if timer “on” activates, quiet operation maintains.
6 After off, when on back, quiet operation is not memorised.
C. Control contents
1 Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2 Manual fan speed for quiet operation is 1 step from setting fan speed.
3 Compressor frequency reduced.
12.2.1 Quiet operation (Heating)
A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1 When one of the following conditions is satisfied, quiet operation stops:
a.
Powerful button is pressed.
b.
Stop by OFF/ON switch.
c.
Timer “off” activates.
d.
Quiet button is pressed again.
2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except fan
only mode.
5 During quiet operation, if timer “on” activates, quiet operation maintains.
6 After off, when on back, quiet operation is not memorised.
C. Control contents
a. Fan Speed Auto
Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger.
Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
b. Fan Speed Manual
Manual fan speed for quiet operation is - 1 step from setting fan speed.
c. Compressor frequency reduced.
Summary of Contents for CS-E9PD3EA
Page 24: ...24 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 25: ...25 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E9PD3EA ...
Page 26: ...26 5 1 2 CS E12PD3EA ...
Page 27: ...27 5 2 Outdoor Unit 5 2 1 CU E9PD3EA 5 2 2 CU E12PD3EA ...
Page 28: ...28 6 Refrigeration Cycle Diagram ...
Page 29: ...29 7 Block Diagram 7 1 CS E9PD3EA CU E9PD3EA ...
Page 30: ...30 7 2 CS E12PD3EA CU E12PD3EA ...
Page 31: ...31 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 34: ...34 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 35: ...35 9 2 Outdoor Unit 9 2 1 CU E9PD3EA ...
Page 36: ...36 9 2 2 CU E12PD3EA ...
Page 37: ...37 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU E9PD3EA ...
Page 39: ...39 10 2 1 2 CU E12PD3EA ...
Page 47: ...47 11 1 6 1 WIRE STRIPPING AND CONNECTING REQUIREMENT ...
Page 62: ...62 14 1 2 CU E12PD3EA ...
Page 66: ...66 15 4 Error Codes Table ...