![Panasonic CS-E9PD3EA Service Manual Download Page 104](http://html1.mh-extra.com/html/panasonic/cs-e9pd3ea/cs-e9pd3ea_service-manual_4251932104.webp)
104
18.3 Piping Length Correction Factor
The characteristic of the unit has to be corrected in accordance with the piping length.
18.3.1 CS-E9PD3EA CU-E9PD3EA
18.3.1.1 Cooling
Capacity
18.3.1.2 Heating
Capacity
Note: The graphs show the factor after added right amount of additional refrigerant.
Piping length (m)
Capa
city
cor
rection
factor
0.90
1.00
1.10
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Range of additional refrigerant charge
Piping length (m)
C
apacity
correc
tion
fac
tor
0.90
1.00
1.10
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Range of additional refrigerant charge
Summary of Contents for CS-E9PD3EA
Page 24: ...24 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 25: ...25 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E9PD3EA ...
Page 26: ...26 5 1 2 CS E12PD3EA ...
Page 27: ...27 5 2 Outdoor Unit 5 2 1 CU E9PD3EA 5 2 2 CU E12PD3EA ...
Page 28: ...28 6 Refrigeration Cycle Diagram ...
Page 29: ...29 7 Block Diagram 7 1 CS E9PD3EA CU E9PD3EA ...
Page 30: ...30 7 2 CS E12PD3EA CU E12PD3EA ...
Page 31: ...31 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 34: ...34 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 35: ...35 9 2 Outdoor Unit 9 2 1 CU E9PD3EA ...
Page 36: ...36 9 2 2 CU E12PD3EA ...
Page 37: ...37 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU E9PD3EA ...
Page 39: ...39 10 2 1 2 CU E12PD3EA ...
Page 47: ...47 11 1 6 1 WIRE STRIPPING AND CONNECTING REQUIREMENT ...
Page 62: ...62 14 1 2 CU E12PD3EA ...
Page 66: ...66 15 4 Error Codes Table ...