![Panasonic CS-E9PD3EA Service Manual Download Page 60](http://html1.mh-extra.com/html/panasonic/cs-e9pd3ea/cs-e9pd3ea_service-manual_4251932060.webp)
60
13.3 Protection Control For Heating Operation
13.3.1 Intake Air Temperature Control
Compressor will operate at maximum frequency if below conditions occur:
1 When the indoor intake air temperature is 30°C or above.
13.3.2 Outdoor Air Temperature Control
The maximum current value is regulated when the outdoor air temperature rises above 14°C in order to avoid
compressor overloading.
13.3.3 Overload Protection Control
The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown in
below figures.
If the heat exchanger temperature exceeds 60°C, compressor will stop.
13.3.4 Cold Draught Operation
When indoor pipe temperature is low, cold draught operation start where indoor fan speed will be reduced.
13.3.5 Deice
Operation
When outdoor pipe temperature and outdoor temperature is low, deice operation start where indoor fan motor and
outdoor fan motor stop and operation LED blinks.
13.3.6 Drain Pump Control
This unit has built-in with drain pump.
Control content
During COOL/DRY mode.
o
During COOL/DRY mode, drain pump starts 10 seconds after indoor fan motor starts.
o
The drain pump turns ON and turns OFF periodically. (ON or OFF duration depends on room temperature).
After COOL/DRY mode, when unit turns OFF (power standby) or changes to HEAT mode.
o
The drain pump turns ON for 60 seconds immediately.
Error
judgment
o
When float switch detects ON signal continuously for 2 minutes 30 seconds, error code H21 are shown.
o
When float switch ON has operated 2 times within 20 minutes, error code H35 are shown.
Summary of Contents for CS-E9PD3EA
Page 24: ...24 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 25: ...25 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E9PD3EA ...
Page 26: ...26 5 1 2 CS E12PD3EA ...
Page 27: ...27 5 2 Outdoor Unit 5 2 1 CU E9PD3EA 5 2 2 CU E12PD3EA ...
Page 28: ...28 6 Refrigeration Cycle Diagram ...
Page 29: ...29 7 Block Diagram 7 1 CS E9PD3EA CU E9PD3EA ...
Page 30: ...30 7 2 CS E12PD3EA CU E12PD3EA ...
Page 31: ...31 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 34: ...34 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 35: ...35 9 2 Outdoor Unit 9 2 1 CU E9PD3EA ...
Page 36: ...36 9 2 2 CU E12PD3EA ...
Page 37: ...37 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU E9PD3EA ...
Page 39: ...39 10 2 1 2 CU E12PD3EA ...
Page 47: ...47 11 1 6 1 WIRE STRIPPING AND CONNECTING REQUIREMENT ...
Page 62: ...62 14 1 2 CU E12PD3EA ...
Page 66: ...66 15 4 Error Codes Table ...