![Panasonic CS-E9PD3EA Service Manual Download Page 65](http://html1.mh-extra.com/html/panasonic/cs-e9pd3ea/cs-e9pd3ea_service-manual_4251932065.webp)
65
15.3 Breakdown Self Diagnosis Function
15.3.1 Self Diagnosis Function (Three Digits Alphanumeric Code)
Once abnormality has occurred during operation, the unit will stop its operation, and OFF/ON operation LED OFF.
OFF indicator does not shown on remote control display.
In operation after breakdown repair, the last error code abnormality will be stored in EEPROM.
To make a diagnosis
1 OFF/ON operation LED OFF and the unit automatically stops the operation, but the OFF indicator does not
shown.
2 Press CHECK button continuously for 5 seconds.
3 “- -” will be displayed on the remote controller display.
4 Press
timer
▲
or
▼
button on the remote control. The error code “H00” (no abnormality) will be displayed.
5 Every press of the button (
▲
or
▼
) will increase the error code number.
6 When the displayed error code matches the unit's error code, OFF/ON operation LED will be ON
continuously.
7 The breakdown diagnosis mode will be cancelled by pressing CHECK button continuously for 5 seconds or
wait for 30 seconds
AC Reset button
When AC Reset button is pressed, the error code
will be reset so that the unit will be able to operate
and recheck if any error occurred.
To display memorized error status:
1 Turn ON the power supply.
2 Press CHECK button continuously for 5 seconds.
3 “- -” will be displayed on the remote controller display.
4 Press
timer
▲
or
▼
button on the remote control. The error code "H00" (no abnormality) will be displayed.
5 Every press of the button (
▲
or
▼
) will increase the error code number.
6 When the displayed error code matches the unit's error code, OFF/ON operation LED will be ON
continuously.
7 The breakdown diagnosis mode will be cancelled by pressing CHECK button continuously for 5 seconds or
wait for 30 seconds.
Summary of Contents for CS-E9PD3EA
Page 24: ...24 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 25: ...25 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E9PD3EA ...
Page 26: ...26 5 1 2 CS E12PD3EA ...
Page 27: ...27 5 2 Outdoor Unit 5 2 1 CU E9PD3EA 5 2 2 CU E12PD3EA ...
Page 28: ...28 6 Refrigeration Cycle Diagram ...
Page 29: ...29 7 Block Diagram 7 1 CS E9PD3EA CU E9PD3EA ...
Page 30: ...30 7 2 CS E12PD3EA CU E12PD3EA ...
Page 31: ...31 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 34: ...34 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 35: ...35 9 2 Outdoor Unit 9 2 1 CU E9PD3EA ...
Page 36: ...36 9 2 2 CU E12PD3EA ...
Page 37: ...37 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU E9PD3EA ...
Page 39: ...39 10 2 1 2 CU E12PD3EA ...
Page 47: ...47 11 1 6 1 WIRE STRIPPING AND CONNECTING REQUIREMENT ...
Page 62: ...62 14 1 2 CU E12PD3EA ...
Page 66: ...66 15 4 Error Codes Table ...