The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.2. Protection Control Features
8.2.1. Delay ON Timer Control
This control is applicable to all kinds of operation mode.
Delay ON timer can be set using remote controller, the unit with timer set will start operate earlier than the setting time. This is to
provide a comfortable environment when reaching the set ON time.
Seventy minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 20 seconds to determine
the indoor intake air temperature and outdoor air temperature in order to judge the operation mode.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
8.2.2. OFF Timer Control
This control is applicable to all kinds of operation mode.
OFF timer can be set using remote controller, the unit with timer set will stop operate at set time.