8.1.3. Indoor Fan Motor Operation
There are 31 fan speed numbers assigned for different fan speed operation at designed conditions, as shown in below table. The
fan speed can be set manually using remote control (5 speeds for cooling mode: Lo, Me-, Me, Me+, Hi; 5 speeds for heating: Lo,
Me-, Me, Me+, Shi) or let it automatically changes depending on the operation and its environment.
Fan
Speed
No.
CS-E9CKP
CS-E12CKP
Remark
Voltage
(V)
Cooling
Dry
Heating
Voltage
(v)
Cooling
Dry
Heating
0
OFF
OFF
OFF
OFF
OFF
OFF
- Hot start control.
- Deice control.
1
2
3.03
3.03
3
3.05
SLo
3.05
SLo
- Soft Dry operation mode.
- ON timer pre-operation (D).
4
3.13
3.13
- Auto operation mode judgment (C/D).
- ON timer preparation sampling (C/D).
5
3.15
3.23
- Auto operation mode judgment (H).
- ON timer preparation sampling (H).
6
3.16
Lo
3.29
Lo
- ON timer pre-operation at Auto fan (C).
7
3.23
Lo
3.34
- ON timer pre-operation at Auto fan for E9CKP
(H).
8
3.24
3.40
9
3.31
Me-
3.44
Me-
10
3.36
3.53
11
3.39
Me-
3.60
Me
- Powerful Mode at Lo fan for E12CKP (C).
12
3.44
3.63
13
3.47
Me
3.66
Lo
- Powerful Mode at Lo fan for E9CKP (C).
- ON timer pre-operation at Auto fan for E12CKP
(H).
14
3.55
Me
3.68
- Powerful Mode at Lo fan for E9CKP (H).
15
3.57
3.71
16
3.60
3.75
Me-
17
3.63
Me+
3.77
Me+
- Powerful Mode at Me- fan (C).
18
3.66
3.83
19
3.68
3.85
20
3.71
3.86
Me
- Powerful Mode at Lo fan for E12CKP (H).
21
3.73
Me+
3.91
- Powerful Mode at Me- fan for E9CKP (H).
22
3.77
3.94
23
3.79
3.98
Me+
- Powerful Mode at Me- fan for E12CKP (H).
24
3.80
4.00
25
3.82
Hi
4.00
Hi
- Powerful mode at Me, Me+ or Hi fan (C).
26
3.85
4.01
27
3.89
4.05
SHi
28
3.90
SHi
4.08
29
3.91
4.11
30
3.93
SHi
4.16
SHi
- Powerful mode at Me, Me+ or Hi fan (H).
31
4.07
4.30
21
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy