Outdoor Unit
5
CS-C45FFH / CU-C45FFH
3-minutes Test Operation Control
Once the compressor is activated, it does not
stop for 3 minutes. It stops immediately with
remote control or indoor unit control panel
ON/OFF button.
Residual Heat Remove Control
Compressor Overcurrent Protection
Compressor Delayed Start Control
Compressor High Pressure Protection
When the compressor is stopped, the outdoor
fan will run at the highest speed for 60 seconds
to remove the residual heat of the condenser.
When the current tested by CT1 or CT2
remains 16A or above for 5 seconds, the
compressor will cease.
When the starting instruction is received, the
compressor will start in 2 seconds.
If the high pressure switch is open, the
compressor will be stopped. The compressor
will restart when the high pressure switch is
closed, but time delay safety control is
available
Compressor Discharge Temp Control
When the discharge temperature is 120
or
above, the compressor will stop and when the
temperature declines to 90
or below, the
compressor will start.
℃
℃