Cooling mode
Soft Dry mode
Cooling mode
Soft Dry mode
Intake Air
temperature
Setting Temperature (standard)
Higher
Standard
Lower
23
℃
25
℃
22
℃
2
℃
0
℃
2
℃
1. An additional heater may make the warm air evenly covering each corner of the room.
2. Indoor Fan Speed Control:
a. Manual Control
The fan speed can be adjusted manually.
b. Auto Control
In the first 10 minutes of operation, the fan speed will be at Low.
17
8.3.
Automatic Mode Operation
Standard for Determining Operation Mode
8.4.
Air Circulation Mode Operation
1. Indoor fan operates at super low speed for 20 seconds.
2.After judging indoor air temperature, the operation is determined and operation continued at the mode determined.
3.After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation includes
cooling mode operation.
4.If automatic mode operation is started while the unit is operating, operation will continue.
If current operation is in cooling mode (including the cooling mode operation when is a part of Soft Dry mode operation)
it will be maintained, and if current operation is not cooling mode, the appropriate operation mode is determined for 20
seconds at super low fan speed.
Then the selected mode will continue.
5.Room temperature adjustment.
CS-C45FFH / CU-C45FFH
8.5.
Indoor Fan Motor Control
Automatic fan speed control
When automatic fan speed set,the available range for fan speed is from Hi to Lo
Basic Fan Speed
Cooling Mode
Operation
Soft Dry
Operation
Manual
Auto
Category
Hi
Me
Lo
SLo STOP
Manual
Auto
Manual Fan Speed Control
Basic fan speed can be manually adjusted (Lo,Hi) by using the fan speed selection button.
※
※
※
Deodorization control
Summary of Contents for CS-C45FFH
Page 8: ...8 4 Dimensions Indoor Unit CS C45FFH CU C45FFH 357 23 5X4 1880 16 5 56 Remote Controller ...
Page 9: ...9 Outdoor Unit CS C45FFH CU C45FFH CU C45FFH 900 620 140 40 5 320 ...
Page 43: ...CS C45FFH CS C45FFH CU C45FFH 43 44 37 38 39 40 41 42 14 13 43 ...
Page 45: ...17 Exploded View CS C45FFH CU C45FFH 45 ...
Page 46: ...CS C45FFH CU C45FFH 46 ...