Outdoor
Indoor
Caution
When the wall is horrow, please be sure to use the sleeve for
tube ass
’
y to prevent dangers caused by mice biting th e
connecting cable.
Fig 6
10.2.2.
Indoor unit Installation
10.2.3.
Outdoor unit installation
Fig.7
Fig.8
24
There are three piping arrangements: left, right and right rear
piping.
1.Drill a hole as the right figure.(Fig7)
2.Insert the piping sleeve to the hole.
3.Fix the bushing to the sleeve.
4.Cut the sleeve until it extrudes about 15 mm from the wall.
5.Finish by sealing the sleeve with putty or caulking
compound at the final stage.
1.Fix the unit on concrete or rigid frame firmly and horizontally
by bold nut (10 mm).
2.When installing at roof, please consider strong wind and
earthquake. P lease fasten the installation stand firmly with
bolt or nails.
After selecting the best location, start installation according to
Indoor /Outdoor Unit Installation Diagram.
CS-C45FFH / CU-C45FFH
620
139
Piping