Connecting the cable to the indoor unit
Screw
Cover
1.Remove the control board cover from the unit by loosening the screw.
2.Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord( 4X2.5mm ),
type designation 245IEC 57 or heavier cord.
3.Secure the cable onto the control board with the clamp.
2
The outdoor unit power supply cord should be connected to an independent power
supply. Power supply cord shall be approved polychloroprene sheathed 5x4.0 mm
flexible cord, type designation 245 IEC 57 or heavier cord.The length of the power
supply cord should be less than 40m. A circuit breaker and a current leakage
protector should be installed.
2
28
Fig 18
10.5.
Connecting Cable and Power Supply Cord
10.5.1.
1.Take away the intake grille.
2.Loosen the four screws, remove the terminal board cover.
(Fig 18)
3.Fix the connecting cable onto the terminals on the control
board.
4.Secure the connecting cable using clamp.( Fig 19)
Note: Connecting cable between indoor unit and outdoor
unit shall be approved polychloroprene sheathed 4 2.5mm
flexible cord, type designation 345 IEC 57 or heavier cord.
×
2
10.5.2.
Connecting the cable to the outdoor unit
10.5.3
.
Connect the power cord to outdoor unit
Fig 19
Connected to
outdoor unit
Fixing tool
Connecting cable
1
2
3
Secure piece
1
2
3
L1
L2
L3
N
L1
L2
L3
N
Terminals on the Indoor
Unit
1
2
3
Colour of wires
Terminals on the Outdoor Unit
1
2
3
L1
L2
L3
N
Connected to circuit breaker
Connected to outdoor unit
L1
L 2
L3
N
Fig 20
Fig 21
CS-C45FFH / CU-C45FFH
To indoor unit
To power supply
Summary of Contents for CS-C45FFH
Page 8: ...8 4 Dimensions Indoor Unit CS C45FFH CU C45FFH 357 23 5X4 1880 16 5 56 Remote Controller ...
Page 9: ...9 Outdoor Unit CS C45FFH CU C45FFH CU C45FFH 900 620 140 40 5 320 ...
Page 43: ...CS C45FFH CS C45FFH CU C45FFH 43 44 37 38 39 40 41 42 14 13 43 ...
Page 45: ...17 Exploded View CS C45FFH CU C45FFH 45 ...
Page 46: ...CS C45FFH CU C45FFH 46 ...