25 (E)
Black level (master pedestal) adjustment
When performing the operations using the controller
When the AW‑RP655 is connected:
1
Press the [IRIS] button several times to turn off
its lamp.
Set the iris to the manual ([MANU]) mode.
2
Turn the [FOCUS/IRIS] dial to stop down the
lens iris.
3
Press the [R/B GAIN/PED] button several
times so that the “PEDESTAL TOTAL” item is
displayed on the LCD panel.
4
Turn the jog dial (main) and adjust the black
level to 0.035 V.
5
If necessary, adjust the iris automatically.
Press the [IRIS] button several times to turn on
its lamp.
When the AW‑RP555 is connected:
1
Press the [IRIS] button several times to turn off
its lamp.
Set the iris to the manual ([MANU]) mode.
2
Turn the [LEVEL] dial of [IRIS] to stop down
the lens iris.
3
Follow the operation steps in “Basic
operations” (page 35), and use the menu to
perform the adjustment.
When the AW‑RP50 is connected:
Refer to the Operating Instructions of the controller.