Z‑axis dial
Used to set the numeric values at the numeric entry items on the Menu Panel AV-HS60C3.
It corresponds to the third from the left of the rotary encoders on the Menu Panel AV-HS60C3.
5 Positioner
Used to set the numeric values at the numeric entry items on the Menu Panel AV-HS60C3.
f
X axis (horizontal direction): Corresponds to the leftmost of the rotary encoders on the Menu Panel AV-HS60C3.
f
Y axis (vertical direction): Corresponds to the second from the left of the rotary encoders on the Menu Panel AV-HS60C3.
6
<FINE> button
Changes the amount of change in parameter for the positioner operation.
When set to on, finer adjustments can be made.
7
<ENBL> button
Lit: Enables operations of the positioner and Z-axis dial.
Off: Disables operations of the positioner and Z-axis dial.
@
@
NOTE
t
This unit detects the position of the positioner and sets the position to the center by the time when the startup is completed after power is turned on.
Do not touch the positioner until the startup of the unit is completed.
r
Memory cards
Memory cards used with the unit should conform to SD or SDHC standards.
Be sure to format memory cards using the unit.
Memory cards with the following capacity can be used for the unit. The unit does not support SDXC memory cards.
SD memory card: 8 MB to 2 GB
SDHC memory card: 4 GB to 32 GB
For the latest information not available in the Operating Guide, visit the following website.
http://pro-av.panasonic.net/ (English only)
f
Keep the following points in mind when using or storing memory cards.
-
Avoid high temperatures/humidities.
-
Do not expose to water droplets.
-
Avoid electrical charges.
Front panel
2 3
2 3
1
1
Power supply 1
Power supply 2
1
<POWER> switch (with safety guard)
Turns power on/off.
f
The single power supply model (AV-HS60C1) does not have the <POWER> switch for the power supply 2.
f
When turning off the power of the redundant power supply model (AV-HS60C2), set both <POWER> switches for the power supply 1 and the
power supply 2 to <OFF>.
2 Power indicator
When power is input into the <AC IN 1>/<AC IN 2> terminal, both <POWER> switches of the power supply 1 and the power supply 2 will light up
when they are set to <ON>.
f
AV-HS60C1 does not have the power indicator for the power supply 2.
3
Alarm indicator <ALARM>
Lights up when the cooling fan of the Control Panel AV-HS60C1/AV-HS60C2 has stopped or when there are problems (voltage declines) with the
power supply. In such cases, an alarm message is displayed on the Menu Panel AV-HS60C3. For the redundant power supply model (AV-HS60C2),
an alarm will be displayed if both <POWER> switches of the power supply 1 and the power supply 2 have not turned on.
When an alarm has occurred, details of the problem can be checked from the <SYS> button on the top menu
→
[MAINTENANCE]
→
[Alarm] tab.
(page 139)
The alarm status can be output from the <GPI I/O> terminal of the Control Panel AV-HS60C1/AV-HS60C2 to external devices.
f
AV-HS60C1 does not have the alarm indicator for the power supply 2.
@
@
NOTE
t
When an alarm has occurred, stop using the unit immediately, and be sure to contact your dealer. Continuous use of the unit even after an alarm has
occurred could damage the unit.
Summary of Contents for AV-HS6000
Page 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Page 45: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Page 144: ...This chapter describes the terminals and signals of the unit Chapter 9 External Interfaces ...
Page 157: ...This chapter describes the setting menu table and terms Chapter 11 Appendix ...
Page 173: ...Web Site http panasonic net Panasonic Corporation 2014 ...