Reference
- 128 -
[MSU] connector (page 26: 6)
HR10G-10R-10SC (71) (Hirose Electric Co., Ltd.)
Pin No.
Function
Flow of signal
1
MSU CONT (H)
CCU→MSU
2
MSU CONT (C)
CCU→MSU
3
MSU DATA (H)
MSU→CCU
4
MSU DATA (C)
MSU→CCU
5
TALLY R
CCU→MSU
6
TALLY G
CCU→MSU
7
HEAD POWER
CCU→MSU
8
ALARM 1
CCU→MSU
9
ALARM 0
CCU→MSU
10
GND
●
Connector of cable
HR10A-10P-10P (73)
1
2
3
4
5
6
7
8
10
9
[MIC1] and [MIC2] connectors (page 26: 7)
HA16RV-3PG(76) (Hirose Electric Co., Ltd.)
Pin No.
Function
Flow of signal
Remarks
1
SHIELD
0 dBm, 600 Ω
2
HOT
CCU→SYSTEM
3
COLD
CCU→SYSTEM
● When connecting to an unbalanced input terminal of an external device, connect to it as shown in the diagram below.
1
3
2
XLR connector
PIN connector
(unbalanced input connector)
1 : Ground (Shield)
2 : Hot (+Ve)
3 : Cold (-Ve)
Be sure to open pin 3.
● Some commercially available conversion connectors and conversion cables have pin 3 shorted to pin 1.
Using such a conversion connector or conversion cable will cause a failure.
NG
Do not use a conversion connector or conversion cable
on which pin 3 is shorted to pin 1.
1
3
2