Picture monitor (PM)
-
30
-
IRIS display
When the information is not displayed on the picture monitor, display it by pressing the [CHARA] button of the ROP.
C1
MEM:F5.6 F4.8
------- --+----------
A
D
B
E
E
E
C
E
A. Camera number
B. IRIS F value
C. IRIS level
D.
IRIS memory
E. TALLY INFO
● Set each item to be displayed on the [PM VIEW SETTING] screen that can be accessed by selecting [MAINTENANCE] on the
CCU menu. However, this screen will not appear if the menu's [IRIS LEVEL] setting is [OFF].
● The IRIS schedule is displayed as follows depending on the setting of [IRIS SCALE] that can be accessed by selecting
[MAINTENANCE] > [SETUP].
IRIS SCALE: FULL
F4.8
C---------+---------O
C:CLOSE O:OPEN
IRIS SCALE: 2STOP
•
In the IRIS level display, the IRIS F value stored in IRIS memory is indicated at the center (+), and the current IRIS F value
is displayed relative to the center as " ".
When the center value (+) and the current IRIS value ( ) overlap, the display shows "
".
F4.8
--------- ---------
•
When the IRIS level falls outside either end of the display range, the status is displayed as a flashing " " or " ".
F4.8
----------+---------
●
TALLY INFO (E)
•
Display the R tally in two segments of the upper row and the R, G, or YL tally in two segments of the lower row.
•
When all R, G, and YL tally signals are ON, the upper row is red, and the left and right segments of the lower row are
green and yellow, respectively.
•
When the R and G tally signals are ON, the upper row is red and the lower row is green.