Reference
- 125 -
Example of mode input connections
1 kΩ
5 V
AK-UCU600
MODE1
MODE2
GND
Example of tally and alarm output connections
AK-UCU600
ALARM
TALLY R OUT
TALLY G OUT
GND
AK-UCU600
ALARM
TALLY R OUT
TALLY G OUT
GND
Withstand voltage: 12 V DC max.
Power current: 100 mA max.
(Max. current 100 mA)
(Max. voltage 12 V)
(Max. current 100 mA)
(Max. voltage 12 V)
[TRUNK] connector (page 26: 3)
JEY-9S-1A3F (LF)(SN) (J.S.T. Mfg. Co., Ltd.)
Pin No.
Function
Flow of signal
Remarks
1
TRUNK1_TX (C)
CAM → CCU
● RS-422 / RS-232C
● Selected using a menu
● Connect to the (C) side during RS-232C connections. The (H) is open.
2
TRUNK1_TX (H)
CAM → CCU
3
TRUNK1_RX (H)
CCU → CAM
4
TRUNK1_RX (C)
CCU → CAM
5
GND
6
TRUNK2_TX (C)
CAM → CCU
7
TRUNK2_TX (H)
CAM → CCU
8
TRUNK2_RX (H)
CCU → CAM
9
TRUNK2_RX (C)
CCU → CAM