Item
Display range
Remarks
BUTTON ASSIGN USER1
NONE
CHARA
BARS
CLEAN
The function assigned to the [USER1] button is displayed here.
BUTTON ASSIGN USER2
NONE
CHARA
MENU/USER1
LOCK
BARS
CLEAN
The function assigned to the [USER2] button is displayed here.
ROP SW
FRONT ONLY
REAR ONLY
SWITCH SELECT
This displays the operating status (front/rear) of the [ROP] connectors.
HOURS CCU
******H
Cumulative CCU operating time is displayed here.
CABLE OPEN
(Off)
This item flashes when the optical fiber multi cable is not connected.
CABLE SHORT
(Off)
This item flashes when the optical fiber multi cable is short-circuited.
CAM RECEIVE LEVEL
■■■■■
The level of the optical signals received by the camera is displayed in 5
gradations.
CCU RECEIVE LEVEL
■■■■■
The level of the optical signals received by the unit is displayed in 5 grad-
ations.
VERSION
- - -
The unit's software version is displayed here.
Operation displays
The operation displays appear at the bottom of the screen for approx. 4 seconds when any of the following operations have been per-
formed with the operation panel of the ROP.
Master gain change
Electronic shutter change
Lens extender change
Scene file change
REF LOAD is changed
FILTER is changed
The display time can be changed from [MAINTENANCE] menu > [PM OPERATION STATUS] > [STATUS DISP TIME].
M A S T E R G A I N 1 2 d B
Item
Display range
Remarks
MASTER GAIN
Setting values on cam-
era
The master gain value is displayed here.
For the setting values, refer to the Operating Instructions for the cam-
era.
SHUTTER
Setting values on cam-
era
The speed of the electronic shutter is displayed here.
For the setting values, refer to the Operating Instructions for the cam-
era.
LENS EXT
1.0
2.0
The magnification of the lens extender is displayed here.
When the magnification of the lens extender is set to 2x, [2.0] is dis-
played. Otherwise, [1.0] is displayed.
SCENE FILE
OFF
1 to 8
This indicates the scene file name.
- 35 -