150
Maintenance and Inspections : Warning System
The following error codes are displayed in the display window if an error occurs in the camera:
Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 147) for countermeasures.
Error Codes
Code No.
Description
Type of warnings
E-11
Video initialisation error
1. System Errors
E-27
Recording control error
1. System Errors
E-30
P2 card removal error
2.
Card removal error
E-34
LCD microcontroller error
1. System Errors
E-38
P2 streaming microcontroller error
1. System Errors
E-39
Abnormal initialization of the AVC-Intra codec board (optional AJ-YBX200G)
1. System Errors
E-3F
Microprocessor error in the camera control circuit.
1. System Errors
E-40
Image sequence or GENLOCK input signal error (in case of 24P, 30P and
25P)
6. Image Sequence Error (24P, 30P, 25P)
E-63
Something is wrong with the system control microprocessor.
1. System Errors
E-6F
Reference signal error.
1. System Errors
00:00:00:11
Errors such as recording to P2 card error
7. Recording Error, 8. Number of Clips
Exceeded, 13. P2 Card Error
1394 Error Codes
Code No.
Description
Recording
Indication in display
window
1394 E-80
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DV format.
Stops
The time code section of the
display window indicates the
appropriate error code that
blinks every two seconds.
1394 E-81
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DVCPRO (25 Mbps) format.
Stops
1394 E-82
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DVCPRO50 (50 Mbps) format.
Stops
1394 E-83
Incorrect signals are being input to the
DVCPRO/DV connector.
Stops
1394 E-84
Signals being input to the DVCPRO/DV
connector are not in DVCPRO or DV
format.
Stops
1394 E-85
Signals being input to the DVCPRO/DV
connector are not 1x speed transfer signals
in DVCPRO HD format.
Stops
1394 E-87
Incorrect audio signals are being input to
the DVCPRO/DV connector.
Continues with no sound.
1394 E-90
No signal is supplied to the DVCPRO/DV
connector.
While the recording mode continues, no
data is recorded on cards unless the
abnormal condition is corrected. If an
error has occurred before recording, then,
recording does not start.
1394 E-91
With the menu option REC MODE set to
DV, copy guard information signals for
recording prohibited data are being input to
the DVCPRO/DV connector.
Stops
1394 E-92
The DVCPRO/DV connector is not properly
connected. The viewfinder indicates the
message "1394 INITIAL ERROR."
No recording in 1394 input mode can be
performed.
AJ-HPX2000P(VQT1D27-5)E.book 150 ページ 2009年11月12日 木曜日 午後8時14分