180
Menu : Menu Description Tables
The ____ in the Adjustable Range column indicates the
preset mode.
MAIN OPERATION
BATTERY/P2CARD
Items/
Data Saved
Adjustable
Range
Remarks
BATTERY
SELECT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON140
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NICD14
TYPE A
TYPE B
Select the battery to use. Remaining
capacity detection is also performed
according to the selected battery.
The variable range is changed by the
item settings selected on the [
BATTERY
SETTING1
] (page 181) and [
BATTERY
SETTING2
] (page 182) menus.
The initial value for TYPE A is set to
DIONIC90 while the same for TYPE B is
set to HYTRON140.
When BP-GL65 or BP-GL95, a battery
made of Sony, is used, set this to "BP-
L65/95".
– C U F –
EXT DC IN
SELECT
AC_ADPT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON140
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NICD14
TYPE A
TYPE B
Set the remaining capacity detection
type when a battery is connected to the
DC IN connector. Remaining capacity
detection is also performed according to
the selected battery type.
The variable range is changed by the
item settings selected on the [
BATTERY
SETTING1
] (page 181) and [
BATTERY
SETTING2
] (page 182) menus.
Analog voltage is displayed on the
viewfinder screen.
When BP-GL65 or BP-GL95, a battery
made of Sony, is used, set this to "BP-
L65/95".
– C U F –
BATT NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT NEAR END ALARM.
– C U F –
BATT NEAR
END CANCEL
ON
OFF
If set to ON, the warning tone and
indication can be canceled by pressing
the MODE CHECK button when BATT
NEAR END ALARM is triggered.
– C U F –
BATT END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT END ALARM.
– C U F –
BATT REMAIN
FULL
70%
100%
Set the display of the remaining battery
level indicator bar in the display window
when a battery with this function is used.
70%:
Indicate FULL at 70% capacity.
100%:
Indicate FULL at 100% capacity.
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
CARD NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep for P2 CARD NEAR END ALARM.
– C U F –
CARD NEAR
END TIME
2min
3min
Set the remaining time to indicate the P2
CARD NEAR END TIME alarm.
– C U F –
CARD END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep for P2 CARD END ALARM.
– C U F –
CARD
REMAIN/
3min/
5min/
Set the length of time for one segment
(
) of the P2 card’s remaining capacity
indicator bars.
3min/
:
One segment represents 3
minutes.
5min/
:
One segment represents 5
minutes.
– C U F –
AJ-HPX2000P(VQT1D27-5)E.book 180 ページ 2009年11月12日 木曜日 午後8時14分