168
Setup: Item Settings
Panasonic camera-recorders, recording formats and recording/stopping signals (Recording Mark)
*1: Recording Marks are not added to the HD SDI signal in default mode.
*2: Only recording format of 1080/**i is available.
180
BATTERY SEL
0000
0001
0002
0003
0004
0005
0006
NiCd12
NiCd13
NiCd14
S-LION
I-LION
TYPE-A
TYPE-B
Sets the battery type.
0: Settings for 1 pc. 12 V battery (NEAR: 11.2 V, END: 10.6 V)
1: Settings for 1 pc. 13 V battery (NEAR: 12.0 V, END: 10.6 V)
2: Settings for 1 pc. 14 V battery (NEAR: 13.6 V, END: 10.6 V)
3: Settings for 1 pc. lithium-ion battery (BP-L90A) (NEAR: 11.0 V, END: 10.6 V)
4: Settings for 1 pc. lithium-ion battery (ENDURA80) (NEAR: 13.4 V, END: 10.6 V)
5: Battery specified by setup menu No. 181 (TYPE-A NEAR) and No. 182 (TYPE-A END).
6: Battery specified by setup menu No. 183 (TYPE-B NEAR) and No. 184 (TYPE-B END).
181
TYPE-A NEAR
0000
|
0023
|
0044
10.6
|
12.9
|
15.0
Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the
voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
• When a setting is made in the vicinity of 15.0 V, the counter display may flash also
when AC power is used.
• A setting that is smaller than END cannot be made.
182
TYPE-A END
0000
|
0018
|
0034
10.6
|
12.4
|
14.0
Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because
the voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
A setting that is larger than NEAR cannot be made.
183
TYPE-B NEAR
0000
|
0023
|
0044
10.6
|
12.9
|
15.0
Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the
voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
• When a setting is made in the vicinity of 15.0 V, the counter display may flash also
when AC power is used.
• A setting that is smaller than END cannot be made.
184
TYPE-B END
0000
|
0018
|
0034
10.6
|
12.4
|
14.0
Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because
the voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
A setting that is larger than NEAR cannot be made.
Model
Recording format
Recording Mark TYPE
Remarks
AJ-HDC27F,H
720/**p over 60p
TYPE1
AJ-HDX400P
1080/59.94i
*1
Provides switching between TYPE1 and TYPE2.
For operating details, see respective operating
instructions.
AJ-HDX400E
1080/50i
*1
1080/25p over 50i
*1
AJ-HDX900
720/59.94p
TYPE1
720/23.98p over 59.94p
TYPE1
720/29.97p over 59.94p
TYPE1
1080/59.94i
*1
1080/23.98p over 59.94i
TYPE2
1080/29.97p over 59.94i
*1
1080/50i
*1
1080/25p over 50i
*1
720/50p
TYPE1
720/50p over 50p
TYPE1
AG-HPX500/502
AG-HPX170/171/172/174
AG-HPX300/301/302/304
AJ-HPX2000/2100
AJ-HPX3000
*2
AJ-HPX2700
AJ-HPX3700
*2
720/**p
TYPE1, 2
1080/**i
TYPE 2
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.