ELE-33
6-5. R,B Gamma(2) Adjustment
BOARD
CAM SYSCON, PREAMP
TP
CAM OUT (75 ohm termination)
ADJUST
VR102[R LVL] (PRE AMP)
VR302[B LVL] (PRE AMP)
EVR
F.NUMBER
See Below
CHART
Gray Scale
M. EQ.
WFM, Vector Scope
SPEC.
Set the vector dots to one dot, then set it on
the origin.
1. Set GAIN to H position.
2. Set
the
EVR
as shown below.
COM:[1E] DATA:[47] ADR:[00] [Enter]
3. Set the lens extender and Ratio converter to
X1
position.
4. Set the
WHITE BAL SW
to
PRE
and execute
ABB
.
5. Press HIGH GAIN button and set to 30dB.
6. Connect a Waveform monitor
to the
CAM OUT
,
and adjust the Iris so that the peak level is
100%
.
7. Set the Camera Recorder switches as shown
below.
SHUTTER
:
1/1000
8. Set the EVR as shown below. (for PAL only)
COM:[0E] DATA:[6C] ADR:[0A] [Enter]
9. If the vector dot is more than one, adjust
EVR
so
that the vector dot is one.
[ R Gamma]
(1)
COM:[0E] DATA:[80] ADR:[09]
[Enter]
(2) Adjust EVR by
[
←
←
←
←
]/[
!
]
.
[ B Gamma]
(1)
COM:[0E] DATA:[6C] ADR:[0A] [Enter]
(2) Adjust EVR by
[
←
←
←
←
]/[
!
]
.
The EVR Variable Data range is
6Ch-94h
,
* Vector Scope, set the Gain is MAX.
10. If the vector dot is not on the origin, adjust
VR102
[R LVL]
and
VR302
[B LVL].
If the vector dot is more than one, adjust
item 9,10
alternately.
11. Press HIGH GAIN button and set to 0dB.
R gamma for V
direction
.
B gamma for H
direction
VR302
VR102
Summary of Contents for AJ-D610WBp
Page 3: ... 3 ...
Page 4: ... 4 ...
Page 5: ... 5 AJ D610WBE ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 9: ... 9 AJ D610WBP ...
Page 10: ... 10 AJ D610WBE ...
Page 11: ...FCD0202NCKK29WB ...
Page 49: ...INF 37 17 Circuit board layout ...
Page 118: ...PRE AMP CDS BLOCK DIAGRAM BLK 4 ...
Page 136: ...1 2 3 4 5 6 7 1 2 2 1 1 2 1 VJB80858 ...
Page 271: ... FOIL SIDE COMPONENT SIDE OPERATE P C BOARD VEP86149A CBA 24 ...