ELE-27
5-5. R,G,B PED TRACK
Adjustment
BOARD
PER PROCESS
TP
CAM OUT ( 75 ohm termination)
ADJUST
VR104 [R TRACK]
VR504 [B TRACK]
EVR
F.NUMBER
-
MODE
-
M. EQ.
Vector Scope
SPEC.
Center of Vector = Center of Vector Scope
Menu Setting
1. While pressing
[SHIFT], [+],
and
[-]
buttons and
set
[MENU]
switch to
SET
.
2. Set data as shown below. (Please take note if the
data is already exist. It is necessary to return
original data again after this adjustment.)
PAGE: MAIN MENU 1/4
→
FLARE/GAMMA
R FLARE
:
0
G FLARE
:
0
B FLARE
:
0
R GAMMA
:
0
B GAMMA
:
0
PAGE: SERVICE ADJ 2/2.
R GAMMA (1)
:
0
B GAMMA (1)
:
0
3. Set the EVR as shown below to change the
pedestal level.
COM:[1E] DATA:[28] ADR:[00]
[Enter]
4. Connect
a
Vector Scope
and set the gain to Max
,
then
adjust
VR104
[R TRACK] and
VR504
[B
TRACK] precisely so that the black dot is on the
origin of the
Vector Scope
.
5. Set the EVR as shown below to change the
pedestal level.
COM:[1E] DATA:[29] ADR:[00]
[Enter]
6. Connect a
Vector Scope,
and confirm that the
black dot is on the origin of the
Vector Scope
. If it
is not adjust
VR104
[R TRACK] and
VR504
[B
TRACK].
7. Repeat item 3 to 6.
8. After this adjustment, input original data which was
changed at step 2.
5-6. PRE AMP DC Adjustment
BOARD
PER AMP
TP
TP104[R-SH], TP204[G-SH], TP304[B-SH]
ADJUST
VR101[R DC], VR201[G DC], VR301[B DC]
F.NUMBER
-
MODE
-
M. EQ.
Oscilloscope
SPEC.
A=0
±
50mVDC
1. Connect an oscilloscope to
TP104
and adjust
VR101
so that the level A (Optical black) is in the
specification.
2. Connect an oscilloscope to
TP204
and adjust
VR201
so that the level A (Optical black) is in the
specification.
3. Connect an oscilloscope to
TP304
and adjust
VR301
so that the level A (Optical black) is in the
specification.
5-7. R,G,B SH Level Adjustment
BOARD
CCD PULSE, SYNC
TP
TP102[R], TP302[G], TP502[B]
(PER PROCESS)
TP3206 (SYNC) for trigger
ADJUST
VR102[R LEVEL] (PER AMP)
VR202[G LEVEL] (PER AMP)
VR302[B LEVEL] (PER AMP), EVR
F.NUMBER
Grayscale Chart
(Reflection Type 3200K)
MODE
F11 + 1/2
M. EQ.
Oscilloscope
SPEC.
A = 666 +/- 10mVp-p
1. Set the Lens Extender to X1.
2. Set the EVR as shown below.
COM:[1E] DATA:[27] ADR:[00] [Enter]
(GAIN L:0dB, KNEE:OFF, TEST PULSE:ON)
3. Connect an oscilloscope to TP3206 (SYNC
Board) for trigger.
4. Connect an oscilloscope to TP102 and adjust
VR102 so that the level A is in the specification.
5. Connect an oscilloscope to TP302 and adjust
VR202 so that the level A is in the specification.
6. Connect an oscilloscope to TP502 and adjust
VR302 so that the level A is in the specification.
VR504
VR104
Level A
(Optical
Black)
A
Summary of Contents for AJ-D610WBp
Page 3: ... 3 ...
Page 4: ... 4 ...
Page 5: ... 5 AJ D610WBE ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 9: ... 9 AJ D610WBP ...
Page 10: ... 10 AJ D610WBE ...
Page 11: ...FCD0202NCKK29WB ...
Page 49: ...INF 37 17 Circuit board layout ...
Page 118: ...PRE AMP CDS BLOCK DIAGRAM BLK 4 ...
Page 136: ...1 2 3 4 5 6 7 1 2 2 1 1 2 1 VJB80858 ...
Page 271: ... FOIL SIDE COMPONENT SIDE OPERATE P C BOARD VEP86149A CBA 24 ...