List of Transition Patterns
Legends
There is a case in which two or more numbers are set for one pattern (duplicate numbers).
•
Example:
The same Mtrix pattern is called regardless of whether 24 or 701 is specified.
When transition is executed by specifying the number in the columns for which “+Diss” is shown, transition mix (Dissolve) is performed.
•
Example:
The same Slide1 pattern is called regardless of whether 43 or 1311 is specified. However, when transition is executed with 43 or 1311
specified, transition wipe or transition mix is performed, respectively.
The COMP SINGLE, COMP BOTH, SLIDE, MULTI, and Blinds patterns are the basic patterns with the corresponding MODIFY effects applied as
•
shown by the arrow marks (
page Vol.2-3). (
Example:
When SLIDE as the MODIFY effect is applied to the No. 1 basic pattern, the No. 43, 1301,
or 1304 pattern is generated.)
+COMP SINGLE
+COMP BOTH
+SLIDE
+MULTI
+Blinds
+MULTI
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Basic
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
A, O, R,
XY
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
28
1501
1521
29
1502
1522
30
1503
1523
31
1504
1524
36
1505
1525
37
1506
1526
38
1507
1527
39
1508
1528
40
1509
1529
41
1510
1530
42
1511
1531
128
1512
1532
129
1513
1533
COMP
SINGLE
+Diss
O,R
O,R
O,R
O,R
O,R
O,R
O,R
O,R
32
1541
33
1542
34
1543
35
1544
130
1545
131
1546
132
1547
133
1548
COMP
BOTH
1505
43
1301
1311
44
1302
1312
45
1303
1313
46
1304
1314
51
1315
52
1306
1316
53
1307
1317
54
1308
1318
SLIDE*
1
+Diss
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
100
101
102
Blinds
MULTI
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
Duplicated
Duplicated
Duplicated
+Diss:
This denotes a pattern to which the dissolve effect can be applied.
A:
Temporary change of aspect ratio is available (
page Vol.1-35).
O:
One-way function is available (
page Vol.1-34). (Only when [BUS] in the [SETUP] menu is set to [AB].)
R:
Reverse function is available (
page Vol.1-35).
XY:
XY position adjustment with the joystick is available (
page Vol.1-34).
Z:
Z position adjustment with the joystick is available (
page Vol.1-34).
*
1
Any SLIDE pattern cannot be used for the downstream key.