7.6
Control Board Connector Overview
FOOT
CONTROL
WARNING
LIGHTS
CONTROL
BOX
HAND HELD
REMOTE (HHR)
POWER PACK
POSITIVE for PC BOARD
(black #2 to 2
and black # 4 to 27)
CYLINDERS
LIFT 15 (2 ea)
BL - Blue
BR - Brown
SW - Black
GE - Yellow
GN - Green
- Negative
+ Positive
Power LED
Control Board Codes:
System ok / ON/OFF switch off, (or missing bridge J11/2<->4)
System ok / ON/OFF switch on, (or bridge J11/2<->4)
Low Voltage
Warning lights shorted
Short in on-off switch or aux port
General short in electrical wiring
Emergency program (all sensors are bypassed).
Activation by: Press Open+Lower>10 seconds
Diagnosis mode activated
Defect at motor solenoid detected during lifting
Voltage V02 (J1 pin 2) is missing, defective fuse
Defect at opening, valve (S3/S4) or motor relay
detected during opening
S5 valve detected during closing or motor solenoid defective
S5 valve detected or defect at lowering valve (S1/S2)
Cab switch: off/on (or disconnect bridge J11/2<->4)
ON/OFF switch (or disconnect bridge J11/2<->4) or close
tail lift
Cab switch: off/on (or disconnect bridge J11/2<->4) or close
tail lift
Cab switch: off/on (or disconnect bridge J11/2<->4) or
voltage interruption MBB control
Cab switch: off/on (or disconnect bridge J11/2<->4)
Automatically when the valves are back to normal
Replace the fuse
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Removing service connector
Code
Description
Reset
SLIDE
UP
N/A
N/A
N/A
N/A
N/A
N/A